BMDZW - WATER STANDARD KIT-A ANTHRACENE-D10, 48807
- MSDS: BMDZW
- Manufacturer: SUPELCO INC
- Product Name: WATER STANDARD KIT-A ANTHRACENE-D10, 48807
- National Stock Number: 6850-00N018228
Product Identification
Product ID:WATER STANDARD KIT-A ANTHRACENE-D10, 48807
MSDS Date:01/01/1987
FSC:6850
NIIN:00N018228
Kit Part:Y
MSDS Number: BMDZW
Responsible Party
BELLEFONTE, PA 16823
US
Emergency Phone: 814-359-3441
Info Phone: 814-359-3441
Cage: 54968
Contractor
Telephone: 314-771-5765/414-273-3850X5996
Cage: 54968
Ingredients
ANTHRACENE; (ANTHRACENE-D10)
CAS: 120-12-7
RTECS: CA9350000
Fraction By Weight: 0.2%
OSHA PEL 0.2 MG/M3
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
METHANE, DICHLORO-; (METHYLENE CHLORIDE).
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 99.98%
OSHA PEL 500 PPM;1000 PPM, C
ACGIH TLV: 50 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:SEE INGREDIENT 2.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATERIALS HAVE PRODUCED
SENSITIZATION OF THE MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS &
COULD HAVE A SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS
(E.G.,EPINEPHRINE) MAY BE CONTRAINDICATED EXC EPT FOR
LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
CHLOROCARBONS . (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:GROUP 2(NTP), GROUP
2B(IARC).
Effects of Overexposure:HLTH HAZ:HARMFUL IF INHALED. MAY BE FATAL IF
SWALLOWED. CONTAINS MATERIAL KNOWN TO STATE OF CALIFORNIA TO CAUSE
CANCER. HEADACHE, NAUSEA, GASTROINTESTINAL DISTURBANCES, BLINDNESS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE:FLUSH W/WATER FOR AT LEAST 15 MIN. CALL MD. SKIN:FLUSH
W/LG VOLS OF WATER. INHAL:IMMED MOVE TO FRESH AIR. IF BRTHG STOPS,
GIVE ARTF RESP. CALL MD. INGEST:NEVER GIVE ANYTHING BY MOUTH TO
UNCON PERS ON. NEVER TRY TO MAKE UNCON PERSON VOMIT. GIVE 2 TBLS OF
BAKING SODA IN GLASS OF WATER. PRESS FINGERS TO BACK OF TONGUE TO
INDUCE VOMITING. IMMED CALL MD.
Fire Fighting
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, ALCOHOL FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE-DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PORODUCTS MAY
INCLUDE HCL & PHOSGENE .
Accidental Release
Spill Release Procedures:TAKE UP W/ABSORBENT MATERIAL. VENTILATE AREA.
METHYLENE CHLORIDE VAPORS ARE HEAVIER THAN AIR & WILL COLLECT IN
LOW AREAS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN SEALED CONTAINER IN COOL, DRY
LOCATION. KEEP AWAY FROM OXIDIZERS. KEEP AWAY FROM IGNITION
SOURCES.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV
RADIATION MAY CAUSE THE FORMATION OF HCL &/OR PHOSGENE . AVOID
EYE/SKIN CO NTACT. AVOID BREATHING VAPORS.
Exposure Controls
Respiratory Protection:WEAR NIOSH/MSHA APPROVED FACE MASK W/ORGANIC
VAPOR CANISTER.
Ventilation:USE ONLY IN WELL VENTILATED AREA.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
HCC:T4
Boiling Pt:B.P. Text:149F,65C
Melt/Freeze Pt:M.P/F.P Text:-144F,-98C
Vapor Pres:100
Vapor Density:1.10
Spec Gravity:0.790 G/ML
Evaporation Rate & Reference:>1 (ETHER = 1).
Solubility in Water:100%
Appearance and Odor:CLEAR, COLORLESS LIQUID.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS, CHROMIC ANHYDRIDE, LEAD PERCHLORATE, PERCHLORIC
ACIDS.
Hazardous Decomposition Products:HCL, PHOSGENE .
Disposal
Waste Disposal Methods:COMPLY W/ALL APPLICABLE FEDERAL, STATE AND LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.